xTool Fire Safety Set 2 for X1/M2/F1/F2 Ultra/F2 UV

xTool Fire Safety Set 2 Automatic CO₂ Fire Extinguishing System for X1, M2, F1 Ultra, F2 Ultra & F2 Ultra UV

Add an extra layer of protection to your laser with the xTool Fire Safety Set 2, xTool's upgraded automatic fire-extinguishing accessory for compatible enclosed machines. It communicates with your laser's built-in flame sensor and can release CO₂ within 1 second of receiving a signal, helping stop a fire before it spreads.

Set 2 is built around a larger 600 mL cylinder that holds about 400 g of CO₂, so one cylinder can support multiple suppression cycles instead of a single use. It also adds gas-level monitoring, motor-stall and operating-status indicators, one-touch manual suppression, and smart discharge control that auto-resets after each release.

This listing is for Fire Safety Set 2, the version specified for the xTool X1, M2, F1 Ultra, F2 Ultra, and F2 Ultra UV. It is not the original Fire Safety Set used with machines such as the S1, M1 Ultra, and P2S.

Swing Design is xTool's largest dealer, and we carry genuine xTool safety accessories to help you protect your machine, your workspace, and your work.

Key Features of the xTool Fire Safety Set 2

  • Smart linked suppression in about 1 second: The Fire Safety Set 2 communicates with your compatible xTool machine for automatic fire extinguishing. When the machine's built-in flame sensor detects a fire, it signals the set to release CO₂ into the enclosed processing area. xTool states that Set 2 releases CO₂ within 1 second of receiving that signal, helping stop a flame before it spreads.
  • Larger cylinder for multiple suppression cycles: Set 2 uses a 600 mL cylinder with about 400 g of CO₂, compared with the original Fire Safety Set's 48 mL cylinders and about 33 g of CO₂. That larger capacity is designed for more than one discharge: 2–3 uses on the X1, 6–8 uses on the M2, and 10–13 uses on F Series machines, depending on the model size. Actual performance may vary.
  • One-touch manual suppression: If you see a flame and want to act immediately, a manual trigger lets you release CO₂ without waiting for the automatic sequence. That gives you a fast emergency option while the set is in its working state.
  • Safety monitoring you can see at a glance: Set 2 watches gas level, motor stall, and operating status, so you can tell whether the system is ready. Gas-level monitoring is a Set 2 upgrade; the original Fire Safety Set does not include it. Because the set uses weight to measure the cylinder, xTool advises leaving the cylinder in place except when you are replacing it.
  • Smart discharge control with auto-reset: The system supports multiple releases and automatically resets after each one, so it can return to a ready state for the next cycle instead of being limited to a single use.
  • Built for enclosed, compatible xTool lasers: Set 2 is designed for closed processing spaces and should be placed horizontally, not upright or at an angle. It is intended for desktop laser machines and works at operating temperatures of 0°C to 35°C (32°F to 95°F). It is not a substitute for supervision, a workshop fire extinguisher, or xTool's own machine safety guidelines.

Compatible xTool Machines

xTool lists these applicable models for Fire Safety Set 2:

  • xTool X1
  • xTool M2
  • xTool F1 Ultra
  • xTool F2 Ultra
  • xTool F2 Ultra UV

xTool currently states that smart linked automatic suppression supports the X1 and M2, with support for additional machines to be added through future software updates. The F Series discharge counts above are published by xTool for this set.

Fire Safety Set 2 is not the original Fire Safety Set. The original version is the one xTool lists for machines such as the F1 Ultra, F2 Ultra, F2 Ultra UV, M1 Ultra, S1, and P2S when you need that earlier 48 mL design.

xTool Fire Safety Set 2 Specifications

Spec Fire Safety Set 2
Suppression type Automatic CO₂ fire extinguishing, linked to the machine
Response time Releases CO₂ within 1 second of receiving a signal from the machine
Cylinder size 600 mL
Max. CO₂ gas volume About 400 g
Fire-suppression uses per cylinder X1: 2–3 discharges; M2: 6–8 discharges; F Series: 10–13 discharges, depending on model size. Actual performance may vary.
Manual release Yes
Gas-level monitoring Yes
Additional monitoring Motor-stall and operating-status indicators
Discharge control Multiple releases with auto-reset after each one
Applicable models X1, M2, F1 Ultra, F2 Ultra, F2 Ultra UV
Current automatic linking X1 and M2; additional model support planned through software updates
Placement Horizontal only
Operating temperature 0°C to 35°C (32°F to 95°F)
Intended use Closed / enclosed processing spaces on compatible desktop laser machines

Fire Safety Set 2 vs. Original Fire Safety Set

Feature Fire Safety Set 2 Original Fire Safety Set
Cylinder size 600 mL 48 mL
Max. CO₂ gas volume About 400 g About 33 g
Fire-suppression uses Multiple discharges per cylinder (see table above) 1 time
Manual release Yes Yes
Gas-level monitoring Yes No
Applicable models X1, M2, F1 Ultra, F2 Ultra, F2 Ultra UV P2S, F1 Ultra, F2 Ultra, F2 Ultra UV, S1, M1 Ultra

What's Included

  • xTool Fire Safety Set 2
  • 600 mL CO₂ Cylinder

Perfect For

Fire Safety Set 2 is a smart add-on for X1, M2, and F Ultra owners who want automatic CO₂ suppression linked to the machine's flame sensor. It fits home workshops, classrooms, sign shops, and small businesses that already run an enclosed xTool laser and want a faster, monitorable backup if a flame starts during cutting or engraving.

It is an additional safety measure, not a reason to leave the machine running unattended.

Recommended Accessories

  • Replacement 600 mL CO₂ Cylinder for Fire Safety Set 2
  • xTool SafetyPro™ AP2 / AP2 Max air purifiers
  • xTool SafetyPro™ IF2 Inline Fan

xTool notes that Fire Safety Set 2 is not suitable for smoke-exhaust systems that cannot perform intelligent linkage. Pair it with compatible xTool filtration when you need automated exhaust control.

Frequently Asked Questions

What is the xTool Fire Safety Set 2? It is xTool's newer automatic fire-extinguishing accessory. It links to a compatible machine, can release CO₂ within 1 second of receiving a fire signal, and uses a larger 600 mL cylinder so it can support multiple suppression cycles.

Which machines is Fire Safety Set 2 compatible with?
xTool lists the X1, M2, F1 Ultra, F2 Ultra, and F2 Ultra UV as applicable models. Smart linked automatic suppression currently supports the X1 and M2, with additional machine support planned through software updates.

Is Fire Safety Set 2 compatible with the xTool X1?
Yes. The X1 is an applicable model, and xTool includes it among the machines that currently support smart linked automatic suppression. On the X1, one cylinder is rated for 2–3 fire-suppression discharges.

Does Fire Safety Set 2 work with the M2, F1 Ultra, F2 Ultra, and F2 Ultra UV?
Yes, those are the applicable models xTool lists for Set 2. The M2 is rated for 6–8 discharges per cylinder. F Series machines are rated for 10–13 discharges, depending on model size; actual performance may vary.

What is the difference between the Fire Safety Set and Fire Safety Set 2?
Set 2 uses a larger 600 mL cylinder with about 400 g of CO₂, supports multiple discharges, and includes gas-level monitoring. The original Fire Safety Set uses 48 mL cylinders with about 33 g of CO₂ and is rated for a single use. Manual release is available on both. Choose Set 2 for X1 and M2, and confirm which version your F Ultra machine needs before ordering.

How fast does Fire Safety Set 2 respond?
xTool states that Set 2 releases CO₂ within 1 second of receiving a signal from the machine.

Can I leave my laser running unattended if I install Fire Safety Set 2?
No. xTool says the fire safety set cannot extinguish all fires or eliminate the risk of danger, and you should not leave the laser unattended while it is working. After a job, inspect and clean the processing area to make sure no flame remains. Keep a separate fire extinguisher in the workspace.

How should I install and place Fire Safety Set 2?
Place it horizontally. Do not stand it vertically or at an angle. Use it only with a closed processing space on a compatible desktop laser, and follow the official installation guide for your machine. After a CO₂ discharge, wait at least 5 minutes before handling the cylinder. The cylinder surface can become extremely cold, and dry ice may form at the entrance.

Does Fire Safety Set 2 replace my workshop fire extinguisher?
No. It is an automatic CO₂ suppression accessory for compatible enclosed xTool lasers. You should still keep proper fire-extinguishing equipment in the workspace and follow all machine safety instructions.

Why buy the xTool Fire Safety Set 2 from Swing Design?
Swing Design is xTool's largest dealer. We offer genuine xTool products, help you match the right fire safety set to your machine, and support you as you build a safer laser workflow.

Automatic Protection for Your xTool Laser

The xTool Fire Safety Set 2 adds linked, 1-second CO₂ suppression, a larger multi-use cylinder, and status monitoring to compatible enclosed lasers, including the X1, M2, F1 Ultra, F2 Ultra, and F2 Ultra UV. Order the xTool Fire Safety Set 2 from Swing Design, xTool's largest dealer, today.

Take Another Look